1673-159X

CN 51-1686/N

薛睿渊,张永楠,张希恒,等. 不同网格划分方式下阀门有限元分析结果差异性研究[J]. 西华大学学报(自然科学版),2024,43(X):1 − 8. doi: 10.12198/j.issn.1673-159X.5212
引用本文: 薛睿渊,张永楠,张希恒,等. 不同网格划分方式下阀门有限元分析结果差异性研究[J]. 西华大学学报(自然科学版),2024,43(X):1 − 8. doi: 10.12198/j.issn.1673-159X.5212
XUE Ruiyuan, ZHANG Yongnan, ZHANG Xiheng, et al. Study on the Difference of Valve Finite Element Analysis Results Under Different Meshing Methods[J]. Journal of Xihua University(Natural Science Edition), 2024, 43(X): 1 − 8.. doi: 10.12198/j.issn.1673-159X.5212
Citation: XUE Ruiyuan, ZHANG Yongnan, ZHANG Xiheng, et al. Study on the Difference of Valve Finite Element Analysis Results Under Different Meshing Methods[J]. Journal of Xihua University(Natural Science Edition), 2024, 43(X): 1 − 8.. doi: 10.12198/j.issn.1673-159X.5212

不同网格划分方式下阀门有限元分析结果差异性研究

Study on the Difference of Valve Finite Element Analysis Results Under Different Meshing Methods

  • 摘要: 网格划分方式关系着阀门有限元分析结果的准确性,但不同网格形式和密度对计算结果的影响趋势还鲜有研究。以某轴流式止回阀的阀芯为例,探讨了在阀门有限元模拟过程中不同软件计算结构的差异及网格划分方式、密度对计算结果的影响。研究结果表明:阀门强度有限元分析结果由前处理及求解设置决定;相对于四面体网格,采用六面体网格划分能有效避免因网格划分引起的应力奇异或者应力集中现象,而且能降低接触面间的网格渗透误差,从而使阀门强度计算结果更为精确,此外六面体网格计算结果更为稳定,受网格密度影响较低。研究成果可为阀门网格划分方式选择及强度分析结果的判定提供指导。

     

    Abstract: The meshing method determines the accuracy of the valve finite element analysis results, but the influence trend of different grid forms and densities on the calculation results has rarely been studied. Taking the spool of an axial check valve as an example, the differences of the calculation results of different software and the influence of meshing and density on the calculation results in the process of valve finite element simulation were discussed. The results show that the finite element analysis results of valve strength are determined by the pretreatment and solution settings. Compared with the tetrahedral mesh, the use of hexahedral meshing can effectively avoid the stress singularity or stress concentration caused by meshing, and can reduce the mesh penetration error between the contact surfaces, so that the valve strength calculation results are more accurate, in addition, the hexahedral mesh calculation results are more stable and less affected by the mesh density. The research results provide guidance for the selection of valve meshing method and the determination of strength analysis results.

     

/